Casestudie

HL-A006 — Trimless Recessed Linear Profile Case Study

Technical review Weili Wu, Engineering Lead Project Name HL-A006 — Marais Pied-à-Terre, Paris Trimless Recessed Lighting Project City Paris, France Project Description Marais Pied-

Helian LED31 juli 2026Leestijd: 1 minuut
Technische beoordeling Weili Wu, Hoofd Engineering

Naam project

HL-A006 — Marais Pied-à-Terre, Paris Trimless Recessed Lighting

Project City

Paris, France

Projectbeschrijving

Marais Pied-à-Terre, a renovated 17th-century apartment in the Marais district of Paris, integrates the HELIAN HL-A006 trimless recessed linear profile into the new drywall ceiling for accent, bed-head and corridor lighting. The "trimless" recessed design lets the profile disappear into the plaster with no visible flange, satisfying the heritage authority's request for minimal ceiling intervention.

Problemen en behoeften van gebruikers

  • Need 1 — Truly trimless installation. The heritage authority prohibited visible flanges, tracks or trim rings on the new drywall.
  • Need 2 — Slim 9 mm source width. The chosen 9 mm-wide LED strip had to fit the profile exactly.
  • Need 3 — Continuous ceiling line. Living-room and corridor runs of 4–6 m required single-direction lines without visible joints.

Oplossing

HELIAN heeft de HL-A006 model uit de A-serie:

  • Hoofdtekst: AL 6063 aluminum with anodized or painted silver surface.
  • Breedte van de lichtbron: 9 mm.
  • Omslag: PC / PMMA; Cover Model BAPL005 / BAPL006.
  • Accessoires: End Cap, Clip, Suspended Rope (Set), Connector.
  • Lengte: 4 m / max.
  • Toepassing: Trimless verzonken in gipsplaat.

Afbeelding van de applicatie

HL-A006 Toepassingsbeeld
HL-A006 Toepassingsbeeld

Resultaten van de implementatie

  • Invisible flange. The plaster skim coat finished flush with the profile opening, leaving only the diffuser face visible.
  • Heritage approval. The trimless profile cleared the heritage authority review with no modifications.
  • 9 mm strip fit. The LED strip dropped into the profile without re-stripping.
  • Continuous ceiling line. 4–6 m runs joined at the support positions with no visible mid-span joints.
  • Gekwantificeerde uitkomst. 86 m of HL-A006 installed across living, bedroom and corridor; the heritage review closed in one cycle and the trimless effect was approved by the architect on first site inspection.
Heb je een route waar nog een stuk aan toegevoegd moet worden?

Geef de strookbreedte, de lengte en de bestemming door — wij zoeken het juiste profiel, de juiste diffusor en de juiste bevestigingsmaterialen uit en sturen u binnen 1 werkdag een offerte.

Dien uw aanvraag in