{"id":25509,"date":"2026-10-27T02:47:27","date_gmt":"2026-10-27T02:47:27","guid":{"rendered":"https:\/\/hlled.com\/?p=25509"},"modified":"2026-11-11T10:13:13","modified_gmt":"2026-11-11T10:13:13","slug":"ip-rating-outdoor-led-profile","status":"publish","type":"post","link":"https:\/\/hlled.com\/fr\/choosing-guides\/ip-rating-outdoor-led-profile\/","title":{"rendered":"How to Choose the Right IP Rating for Outdoor LED Profiles"},"content":{"rendered":"<p class=\"wp-block-paragraph\">An aluminum profile carries no IP rating out of the box. The rating belongs to the assembled system: extrusion, cover, end caps, sealant and strip together. IP65 is the practical minimum for anything rained on directly. Where water collects sets the number, not how exposed the wall looks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Most specifications skip that distinction. It is why outdoor fixtures fail while every part on the purchase order was individually rated.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What do the two digits tell you?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The IP code comes from IEC 60529. The first digit covers solids, the second covers liquids. For LED profiles the first digit is always 6, so dust-tight is a given. The decision sits entirely in the second digit.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Rating<\/th><th>Liquid protection<\/th><th>Where it belongs<\/th><th>Where it fails<\/th><\/tr><\/thead><tbody><tr><td>IP44<\/td><td>Splashing water<\/td><td>Sheltered outdoor: under a canopy, arcade, soffit<\/td><td>Direct rain, wind-driven spray<\/td><\/tr><tr><td>IP65<\/td><td>Low-pressure water jets from any direction<\/td><td>Exposed walls, facades, patios. The outdoor baseline<\/td><td>Standing water, pooled drainage, immersion<\/td><\/tr><tr><td>IP66<\/td><td>Powerful water jets<\/td><td>Wash-down zones, storm-exposed sites, coastal facades<\/td><td>Immersion<\/td><\/tr><tr><td>IP67<\/td><td>Temporary immersion, 1 m for 30 minutes<\/td><td>Ground level, step lights, fountain edges, flood-prone recesses<\/td><td>Continuous immersion<\/td><\/tr><tr><td>IP68<\/td><td>Continuous immersion, depth set by the maker<\/td><td>Pools, water features, submerged architectural lighting<\/td><td>Depth beyond the maker&#8217;s stated limit<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Most specifiers skip two of these. IP66 sits between 65 and 67, and it suits a facade taking driven rain or periodic washing. It is stricter on jet pressure without the immersion requirement. Specifiers often over-specify IP44 into sheltered positions where it was adequate.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The profile is not waterproof on its own<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Procurement documents usually get this wrong.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An extrusion is an open channel. Clip a diffuser in and a seam still runs along both sides, where the cover slides into the groove. That seam is a capillary path, not a seal. End caps often arrive with cable holes. Cut ends expose the strip. Aluminum resists corrosion, but corrosion resistance and ingress prevention are different properties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industry guidance is explicit where it exists. The profile alone is not waterproof; it needs a sealant to reach a reliable IP65 or better. The logic runs both ways. One under-rated component compromises the whole assembly, however good the rest of it is.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So the honest framing for a specification is this:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The IP rating is a property of the finished luminaire. The profile is one of five parts that decide it, and the only one that cannot be sealed at the factory.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the trade, &#8220;waterproof profile&#8221; means a profile designed to seal: gasketed groove, closed end caps, cable gland provision. It does not mean the profile arrives at IP67.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Which four seals decide the rating?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Every <a href=\"https:\/\/hlled.com\/fr\/choosing-guides\/led-profile-for-bathroom-wet-area\/\" target=\"_blank\">wet-area failure<\/a> traces back to one of four joints. This list follows the order they usually fail.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Seal point<\/th><th>What goes wrong<\/th><th>What fixes it<\/th><\/tr><\/thead><tbody><tr><td>Cover-to-channel seam<\/td><td>Water wicks along the groove by capillary action<\/td><td>Neutral-cure silicone bead along the groove before the cover is seated<\/td><\/tr><tr><td>End caps<\/td><td>Caps with cable holes let water straight in; friction caps leak under pressure<\/td><td>Closed caps, or glanded caps, plus sealant around the cap edge and the cable exit<\/td><\/tr><tr><td>Cable entry<\/td><td>The single most common leak point on any outdoor fixture<\/td><td>Cable gland sized to the cable (PG7\/PG9\/PG11), plus sealant under the gland nut<\/td><\/tr><tr><td>Field cuts<\/td><td>Every cut end exposes the PCB and its pads<\/td><td>Seal at once with silicone end caps and a bead over the cut face<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1400\" height=\"700\" src=\"https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points.png\" alt=\"Diagram of four sealing points on an outdoor LED profile: cover seam, end cap, cable entry and field cut\" class=\"wp-image-25516\" title=\"\" srcset=\"https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points.png 1400w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points-500x250.png 500w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points-1024x512.png 1024w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points-150x75.png 150w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points-768x384.png 768w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points-18x9.png 18w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Four joints, in the order they usually fail.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Two notes are easy to miss. Silicone sealant has to be neutral-cure. The acetic-cure grades used for glazing corrode the copper traces and the aluminum. Sealant also needs to cure before the fixture is energized and before it sees rain. Allow 24 hours. Shortcuts here stay invisible until the following season.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why most outdoor failures are not IP failures<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An IP rating tests two things: solids and liquids, under defined laboratory conditions. It does not test ultraviolet exposure, salt spray, thermal cycling or condensation. A fixture can hold its IP65 through every test and still degrade in two years outdoors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Four failure modes sit outside the rating.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Drainage.<\/strong> Water that can run off does not need excluding. Fit a drip loop before the cable entry. Angle the body so water sheds away from the seam. That run survives conditions which would defeat a better-sealed but flat-mounted fixture.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Condensation.<\/strong> A sealed chamber cycling between day and night temperatures pulls moisture out of the trapped air. It condenses on the coldest surface, usually the aluminum, and sits there. A hydrophobic breather or a desiccant sachet in the junction box does more than another bead of silicone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>UV.<\/strong> The rating says nothing about it. Covers degrade, gaskets harden, and the seam that was tight in year one opens in year four. That is why the cover material matters as much as the seal. See our note on <a href=\"\/fr\/choosing-guides\/pc-vs-pmma-diffuser\/\" target=\"_blank\">PC versus PMMA covers<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Salt and chemicals.<\/strong> Standard ingress tests use fresh water. Coastal and industrial sites need a marine-grade approach even when the IP number is high. Chloride attack is a corrosion problem, not an ingress problem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What we supply, and what we do not claim<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We publish 11 profiles designed for outdoor and wet-area use. They share three structural features: a gasketed or tight-fitting cover groove, closed end caps, and provision for a cable entry. Dimensions appear here because the section is what constrains the sealing options.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Mod\u00e8le<\/th><th>Inner width<\/th><th>Outer W \u00d7 H (mm)<\/th><th>Mounting<\/th><th>Cover<\/th><\/tr><\/thead><tbody><tr><td>HL-BAPL067-F<\/td><td>8 mm<\/td><td>10.3 \u00d7 10.3<\/td><td>coin<\/td><td>PMMA<\/td><\/tr><tr><td>HL-BAPL065-F<\/td><td>9 mm<\/td><td>11.4 \u00d7 12.2<\/td><td>surface<\/td><td>PMMA<\/td><\/tr><tr><td>HL-BAPL066-F<\/td><td>10 mm<\/td><td>12.3 \u00d7 10<\/td><td>surface<\/td><td>PMMA<\/td><\/tr><tr><td>HL-BAPL068-F<\/td><td>10 mm<\/td><td>16 \u00d7 16<\/td><td>surface<\/td><td>PC<\/td><\/tr><tr><td>HL-BAPL071-F<\/td><td>10 mm<\/td><td>17.1 \u00d7 15.4<\/td><td>surface<\/td><td>PC<\/td><\/tr><tr><td>HL-BAPL069-F<\/td><td>11 mm<\/td><td>17 \u00d7 14<\/td><td>surface<\/td><td>PC<\/td><\/tr><tr><td>HL-BAPL070-F<\/td><td>13 mm<\/td><td>15 \u00d7 17<\/td><td>surface<\/td><td>PC<\/td><\/tr><tr><td>HL-3030F<\/td><td>19 mm<\/td><td>30 \u00d7 30<\/td><td>coin<\/td><td>none<\/td><\/tr><tr><td>HL-BAPL068<\/td><td>25 mm<\/td><td>40 \u00d7 61<\/td><td>suspendu<\/td><td>PC<\/td><\/tr><tr><td>HL-A041<\/td><td>8 mm<\/td><td>94 \u00d7 45.6<\/td><td>suspendu<\/td><td>none<\/td><\/tr><tr><td>HL-A081<\/td><td>61 mm<\/td><td>75 \u00d7 60.4<\/td><td>suspendu<\/td><td>PC<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/hlled.com\/wp-content\/uploads\/2024\/07\/067f.png\" alt=\"HL-BAPL067-F corner LED profile, 10.3 by 10.3 mm, the smallest body in the wet-area group\" class=\"\" title=\"\"><figcaption class=\"wp-element-caption\">HL-BAPL067-F \u2014 10.3 \u00d7 10.3 mm, the smallest section in the wet-area group.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Six of the eleven carry a PC cover and three carry PMMA. That follows the outdoor logic above. Use PC where impact or UV-stabilized performance matters, and PMMA on the small bodies where clarity is the point.<\/p>\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/hlled.com\/wp-content\/uploads\/2024\/06\/068f.png\" alt=\"HL-BAPL068-F surface mounted LED profile, 16 by 16 mm, with closed end caps\" title=\"\"><figcaption class=\"wp-element-caption\">HL-BAPL068-F \u2014 16 \u00d7 16 mm, with closed end caps and a PC cover.<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/hlled.com\/wp-content\/uploads\/2024\/07\/HL-A081.png\" alt=\"Large suspended LED profile HL-A081, 75 by 60.4 mm, in the wet-area group\" title=\"\"><figcaption class=\"wp-element-caption\">HL-A081 \u2014 75 \u00d7 60.4 mm, the largest body in the group.<\/figcaption><\/figure>\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"428\" height=\"463\" src=\"https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/profile-recessed-into-concrete.jpg\" alt=\"Section diagram of an LED profile recessed into a concrete slab with a narrow slot\" class=\"wp-image-25632\" title=\"\" srcset=\"https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/profile-recessed-into-concrete.jpg 428w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/profile-recessed-into-concrete-139x150.jpg 139w, https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/profile-recessed-into-concrete-11x12.jpg 11w\" sizes=\"(max-width: 428px) 100vw, 428px\" \/><figcaption class=\"wp-element-caption\">Section: recessed into concrete. The slot is the only path in \u2014 and the only place to seal.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">We do not claim an IP rating for these profiles. The assembled fixture and the site work establish it, and quoting a number for an unassembled extrusion would misrepresent what we have tested. Our published IP68 certificate covers the <a href=\"https:\/\/hlled.com\/fr\/comparisons\/silicone-neon-vs-aluminum-profile\/\" target=\"_blank\">LED neon range<\/a>, tested to EN 60529: HL-NT1615V24IP68 and the related NS and NV models. It does not extend to aluminum profiles. That scope sits on the <a href=\"\/fr\/certificates\/\" target=\"_blank\">certificates page<\/a>, not in inference.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Should you specify IP68?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Usually not, and the reasons are physical, not commercial.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">IP68 needs a fully sealed chamber, by potting or compression glands. That adds weight, makes field servicing difficult, and traps heat around the strip. A sealed chamber cannot convect, so it runs hotter. A hotter strip loses output faster. The higher rating can shorten life if nobody re-checks the thermal side.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">IP68 belongs underwater. For a wall that takes rain, IP65 with correct seals and drainage beats a badly installed IP68. In both cases the failure mode is the joint, not the number.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Is an aluminum LED profile waterproof by itself?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. An extrusion is an open channel: the cover groove is a capillary seam, and end caps often have cable holes. Water resistance comes when the cover, caps and cable entry seal during assembly. The profile is designed to be sealed. It does not arrive sealed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Do I need IP65 or IP67 for a patio?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IP65 if the run sits under a roof line, a soffit or a canopy and water cannot pool. IP67 if the profile sits at or near ground level, in a recess that collects water, or beside a water feature. Standing water decides it, not how exposed the position looks.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can I upgrade a standard profile to IP65 with silicone?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sometimes, but not reliably. It depends on whether the cover groove holds a bead, whether closed end caps exist for that section, and whether there is cable-gland provision. A profile without those stays a sheltered-area product.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does a higher IP rating mean a longer service life?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. The rating covers ingress of solids and liquids under laboratory conditions. It says nothing about UV, salt spray, thermal cycling or condensation, and those degrade most outdoor fixtures. Drainage, cover material and heat management matter as much as the number.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Do your profiles come with an IP rating?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. We supply 11 profiles designed to be sealed for outdoor and wet-area use, with gasketed grooves, closed caps and cable-entry provision. The assembled fixture and the site sealing establish the rating. So we specify the section and the sealing method, not a number for the extrusion alone.<\/p>\n<style>\r\n.lwrp.link-whisper-related-posts{\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            font-size: 20px;\r\n        }.lwrp .lwrp-description{\r\n            color: #5b5757;\r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(50% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            \r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n            object-fit: cover;\r\n            aspect-ratio: 1 \/ 1;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n            font-size: 18px;\r\n            font-weight: 400;\r\n            \r\n        }@media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }.lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                \r\n                \r\n                \r\n            };\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Articles connexes<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                            <div class=\"lwrp-list-multi-container\">\r\n                    <ul class=\"lwrp-list lwrp-list-double lwrp-list-left\">\r\n                        <li class=\"lwrp-list-item\"><a href=\"https:\/\/hlled.com\/fr\/company-news\/light-building-2026-frankfurt\/\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Shenzhen Helian Electronics (HLLED) a conclu avec succ\u00e8s sa participation au salon Light + Building 2026 de Francfort<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/hlled.com\/fr\/knowledge\/how-much-watt-led-bulb-required-for-a-room\/\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Combien de watts d'ampoules LED sont n\u00e9cessaires pour une pi\u00e8ce\uff1f<\/span><\/a><\/li>                    <\/ul>\r\n                    <ul class=\"lwrp-list lwrp-list-double lwrp-list-right\">\r\n                        <li class=\"lwrp-list-item\"><a href=\"https:\/\/hlled.com\/fr\/videos\/hl-ca001-up-and-down-led-linear-pendant-light\/\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">HL-CA001 Up and Down LED Linear Pendant Light: Specification &amp; Installation Guide<\/span><\/a><\/li><li class=\"lwrp-list-item\"><a href=\"https:\/\/hlled.com\/fr\/how-to\/aluminum-profile-thickness-for-outdoor\/\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Quelle \u00e9paisseur de profil\u00e9 d'aluminium est la meilleure pour les installations de LED en ext\u00e9rieur ? (avec ventilation des techniques d'imperm\u00e9abilisation)<\/span><\/a><\/li>                    <\/ul>\r\n                <\/div>\r\n                        <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>An aluminum profile carries no IP rating out of the box \u2014 the rating belongs to the assembled system. What IP65, IP66 and IP67 each cover, the four seals that decide it, and why most outdoor failures are not ingress failures.<\/p>","protected":false},"author":1,"featured_media":25516,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kb_optimizer_status":2,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[687],"tags":[],"class_list":["post-25509","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-choosing-guides"],"acf":{"hl_has_review":true,"hl_reviewers":[{"person":"weili-wu","kind":"technical","c_name":"","c_role":"","c_url":"","c_bio":""},{"person":"evan-ding","kind":"copy","c_name":"","c_role":"","c_url":"","c_bio":""}]},"taxonomy_info":{"category":[{"value":687,"label":"Choosing Guides"}]},"featured_image_src_large":["https:\/\/hlled.com\/wp-content\/uploads\/2026\/10\/led-profile-four-seal-points-1024x512.png",1024,512,true],"author_info":{"display_name":"Helian LED Lighting","author_link":"https:\/\/hlled.com\/fr\/author\/helian-led-lighting\/"},"comment_info":0,"category_info":[{"term_id":687,"name":"Choosing Guides","slug":"choosing-guides","term_group":0,"term_taxonomy_id":687,"taxonomy":"category","description":"Guides to choosing LED aluminum profiles by application, strip width, diffuser and finish \u2014 practical criteria for specifiers, contractors and installers.","parent":0,"count":8,"filter":"raw","cat_ID":687,"category_count":8,"category_description":"Guides to choosing LED aluminum profiles by application, strip width, diffuser and finish \u2014 practical criteria for specifiers, contractors and installers.","cat_name":"Choosing Guides","category_nicename":"choosing-guides","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/posts\/25509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/comments?post=25509"}],"version-history":[{"count":0,"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/posts\/25509\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/media\/25516"}],"wp:attachment":[{"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/media?parent=25509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/categories?post=25509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hlled.com\/fr\/wp-json\/wp\/v2\/tags?post=25509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}